Review




Structured Review

ViVitro Labs Inc pulsatile flow pump superpump
Pulsatile Flow Pump Superpump, supplied by ViVitro Labs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/pulsatile+flow+pump+superpump/pulsatile+pump+superpump+ar+series/pm38739218-171-197-207
Average 90 stars, based on 1 article reviews
pulsatile flow pump superpump - by Bioz Stars, 2026-09
90/100 stars

Images

Related Articles

Imaging:

Article Title: Scoping review of magnetic resonance motion imaging phantoms.
Article Snippet: MPs are important for validating the integrated imaging systems, ensuring that the fusion of PET and MRI data is both accurate and reliable in situations with physiologic Table 5 Summary of cardiac-dilative phantoms Citation Application Construction Chambers Actuator Beats per minute Stroke volume (mL) Huang et al. [50] PET-MR: Motion artifact generation 18F radioactive gel between balloons 1 Respirator 65 Not reported Tavakoli et al. [44] Pathologic cardiac MR Cast polyvinyl alcohol 2 Syringe Not reported 0–6.5 Groen et al. [51] Comparing CT and MRI for calculating heart parameters Commercial Anthropomorphic heart phantom (Limbs & Things, Bristol, UK) 1 Gas pump 50–100 Not reported Khan et al. [25] Motion artifact generation Cast silicone gel 1 Flow pump Not reported Not reported Swailes et al. [9] Motion artifact generation Cast silicone (Dragon Skin, Smooth-On, Easton, PA) 2 RS-385 Motor with camshaft on syringe 100 max Not reported Fieseler et al. [10] Motion artifact generation in PET-MR Deformable left ventricle model (BSI, Germany), Lumirem® and 18F-FDG 1 Hydraulic flow system 50 Not reported Irwan et al. [52] MRI sequence development Commercial Anthropomorphic heart phantom (Limbs & Things, Bristol, UK) 1 Gas pump 60–80 Not reported Cygan et al. [45] Strain imaging Cast polyvinyl alcohol 1 Pulsatile flow pump SuperPump (Vivitro, Canada) 2–220 150 max Tavakoli et al. [23] Cardiac tracking Cast polyvinyl alcohol 2 CardioFlow 5000 MR Programmable Physiological Flow Pump Not reported Not reported Corrado et al. [46] MRI sequence development 3D-printed polyvinyl alcohol mold for silicone 1 Pulsatile flow pump PD-1100 (BDC Laboratories, Wheat Ridge, CO) 80 Not reported Okafor et al. [47] MRI sequence development Not reported 1 Piston pump 70 Not reported Evans et al. [48] MRI image interpretation Polyethylene sponge covered in silicone rubber 1 Fluid pump 5–150 300 max Debatin et al. [49] Comparing CT and MRI 1 cm thick foam covered on both sides with vulcanized rubber 2 Dual-phase pulsatile flow pump 60 5–50 motion.

Article Title: Feasibility and Technical Aspects of Proximal Nellix-in-Nellix Extension for Late Caudal Endograft Migration.
Article Snippet: Silicone anatomical models were used in conjunction with a pulsatile flow pump (SuperPump; Vivitro Labs Inc, Victoria, British Columbia, Canada).

Positron Emission Tomography:

Article Title: Scoping review of magnetic resonance motion imaging phantoms.
Article Snippet: MPs are important for validating the integrated imaging systems, ensuring that the fusion of PET and MRI data is both accurate and reliable in situations with physiologic Table 5 Summary of cardiac-dilative phantoms Citation Application Construction Chambers Actuator Beats per minute Stroke volume (mL) Huang et al. [50] PET-MR: Motion artifact generation 18F radioactive gel between balloons 1 Respirator 65 Not reported Tavakoli et al. [44] Pathologic cardiac MR Cast polyvinyl alcohol 2 Syringe Not reported 0–6.5 Groen et al. [51] Comparing CT and MRI for calculating heart parameters Commercial Anthropomorphic heart phantom (Limbs & Things, Bristol, UK) 1 Gas pump 50–100 Not reported Khan et al. [25] Motion artifact generation Cast silicone gel 1 Flow pump Not reported Not reported Swailes et al. [9] Motion artifact generation Cast silicone (Dragon Skin, Smooth-On, Easton, PA) 2 RS-385 Motor with camshaft on syringe 100 max Not reported Fieseler et al. [10] Motion artifact generation in PET-MR Deformable left ventricle model (BSI, Germany), Lumirem® and 18F-FDG 1 Hydraulic flow system 50 Not reported Irwan et al. [52] MRI sequence development Commercial Anthropomorphic heart phantom (Limbs & Things, Bristol, UK) 1 Gas pump 60–80 Not reported Cygan et al. [45] Strain imaging Cast polyvinyl alcohol 1 Pulsatile flow pump SuperPump (Vivitro, Canada) 2–220 150 max Tavakoli et al. [23] Cardiac tracking Cast polyvinyl alcohol 2 CardioFlow 5000 MR Programmable Physiological Flow Pump Not reported Not reported Corrado et al. [46] MRI sequence development 3D-printed polyvinyl alcohol mold for silicone 1 Pulsatile flow pump PD-1100 (BDC Laboratories, Wheat Ridge, CO) 80 Not reported Okafor et al. [47] MRI sequence development Not reported 1 Piston pump 70 Not reported Evans et al. [48] MRI image interpretation Polyethylene sponge covered in silicone rubber 1 Fluid pump 5–150 300 max Debatin et al. [49] Comparing CT and MRI 1 cm thick foam covered on both sides with vulcanized rubber 2 Dual-phase pulsatile flow pump 60 5–50 motion.

Article Title: Feasibility and Technical Aspects of Proximal Nellix-in-Nellix Extension for Late Caudal Endograft Migration.
Article Snippet: Silicone anatomical models were used in conjunction with a pulsatile flow pump (SuperPump; Vivitro Labs Inc, Victoria, British Columbia, Canada).

Magnetic Resonance Imaging:

Article Title: Scoping review of magnetic resonance motion imaging phantoms.
Article Snippet: MPs are important for validating the integrated imaging systems, ensuring that the fusion of PET and MRI data is both accurate and reliable in situations with physiologic Table 5 Summary of cardiac-dilative phantoms Citation Application Construction Chambers Actuator Beats per minute Stroke volume (mL) Huang et al. [50] PET-MR: Motion artifact generation 18F radioactive gel between balloons 1 Respirator 65 Not reported Tavakoli et al. [44] Pathologic cardiac MR Cast polyvinyl alcohol 2 Syringe Not reported 0–6.5 Groen et al. [51] Comparing CT and MRI for calculating heart parameters Commercial Anthropomorphic heart phantom (Limbs & Things, Bristol, UK) 1 Gas pump 50–100 Not reported Khan et al. [25] Motion artifact generation Cast silicone gel 1 Flow pump Not reported Not reported Swailes et al. [9] Motion artifact generation Cast silicone (Dragon Skin, Smooth-On, Easton, PA) 2 RS-385 Motor with camshaft on syringe 100 max Not reported Fieseler et al. [10] Motion artifact generation in PET-MR Deformable left ventricle model (BSI, Germany), Lumirem® and 18F-FDG 1 Hydraulic flow system 50 Not reported Irwan et al. [52] MRI sequence development Commercial Anthropomorphic heart phantom (Limbs & Things, Bristol, UK) 1 Gas pump 60–80 Not reported Cygan et al. [45] Strain imaging Cast polyvinyl alcohol 1 Pulsatile flow pump SuperPump (Vivitro, Canada) 2–220 150 max Tavakoli et al. [23] Cardiac tracking Cast polyvinyl alcohol 2 CardioFlow 5000 MR Programmable Physiological Flow Pump Not reported Not reported Corrado et al. [46] MRI sequence development 3D-printed polyvinyl alcohol mold for silicone 1 Pulsatile flow pump PD-1100 (BDC Laboratories, Wheat Ridge, CO) 80 Not reported Okafor et al. [47] MRI sequence development Not reported 1 Piston pump 70 Not reported Evans et al. [48] MRI image interpretation Polyethylene sponge covered in silicone rubber 1 Fluid pump 5–150 300 max Debatin et al. [49] Comparing CT and MRI 1 cm thick foam covered on both sides with vulcanized rubber 2 Dual-phase pulsatile flow pump 60 5–50 motion.

Article Title: Feasibility and Technical Aspects of Proximal Nellix-in-Nellix Extension for Late Caudal Endograft Migration.
Article Snippet: Silicone anatomical models were used in conjunction with a pulsatile flow pump (SuperPump; Vivitro Labs Inc, Victoria, British Columbia, Canada).

Positron Emission Tomography-Magnetic Resonance Imaging:

Article Title: Scoping review of magnetic resonance motion imaging phantoms.
Article Snippet: MPs are important for validating the integrated imaging systems, ensuring that the fusion of PET and MRI data is both accurate and reliable in situations with physiologic Table 5 Summary of cardiac-dilative phantoms Citation Application Construction Chambers Actuator Beats per minute Stroke volume (mL) Huang et al. [50] PET-MR: Motion artifact generation 18F radioactive gel between balloons 1 Respirator 65 Not reported Tavakoli et al. [44] Pathologic cardiac MR Cast polyvinyl alcohol 2 Syringe Not reported 0–6.5 Groen et al. [51] Comparing CT and MRI for calculating heart parameters Commercial Anthropomorphic heart phantom (Limbs & Things, Bristol, UK) 1 Gas pump 50–100 Not reported Khan et al. [25] Motion artifact generation Cast silicone gel 1 Flow pump Not reported Not reported Swailes et al. [9] Motion artifact generation Cast silicone (Dragon Skin, Smooth-On, Easton, PA) 2 RS-385 Motor with camshaft on syringe 100 max Not reported Fieseler et al. [10] Motion artifact generation in PET-MR Deformable left ventricle model (BSI, Germany), Lumirem® and 18F-FDG 1 Hydraulic flow system 50 Not reported Irwan et al. [52] MRI sequence development Commercial Anthropomorphic heart phantom (Limbs & Things, Bristol, UK) 1 Gas pump 60–80 Not reported Cygan et al. [45] Strain imaging Cast polyvinyl alcohol 1 Pulsatile flow pump SuperPump (Vivitro, Canada) 2–220 150 max Tavakoli et al. [23] Cardiac tracking Cast polyvinyl alcohol 2 CardioFlow 5000 MR Programmable Physiological Flow Pump Not reported Not reported Corrado et al. [46] MRI sequence development 3D-printed polyvinyl alcohol mold for silicone 1 Pulsatile flow pump PD-1100 (BDC Laboratories, Wheat Ridge, CO) 80 Not reported Okafor et al. [47] MRI sequence development Not reported 1 Piston pump 70 Not reported Evans et al. [48] MRI image interpretation Polyethylene sponge covered in silicone rubber 1 Fluid pump 5–150 300 max Debatin et al. [49] Comparing CT and MRI 1 cm thick foam covered on both sides with vulcanized rubber 2 Dual-phase pulsatile flow pump 60 5–50 motion.

Article Title: Feasibility and Technical Aspects of Proximal Nellix-in-Nellix Extension for Late Caudal Endograft Migration.
Article Snippet: Silicone anatomical models were used in conjunction with a pulsatile flow pump (SuperPump; Vivitro Labs Inc, Victoria, British Columbia, Canada).

Sequencing:

Article Title: Scoping review of magnetic resonance motion imaging phantoms.
Article Snippet: MPs are important for validating the integrated imaging systems, ensuring that the fusion of PET and MRI data is both accurate and reliable in situations with physiologic Table 5 Summary of cardiac-dilative phantoms Citation Application Construction Chambers Actuator Beats per minute Stroke volume (mL) Huang et al. [50] PET-MR: Motion artifact generation 18F radioactive gel between balloons 1 Respirator 65 Not reported Tavakoli et al. [44] Pathologic cardiac MR Cast polyvinyl alcohol 2 Syringe Not reported 0–6.5 Groen et al. [51] Comparing CT and MRI for calculating heart parameters Commercial Anthropomorphic heart phantom (Limbs & Things, Bristol, UK) 1 Gas pump 50–100 Not reported Khan et al. [25] Motion artifact generation Cast silicone gel 1 Flow pump Not reported Not reported Swailes et al. [9] Motion artifact generation Cast silicone (Dragon Skin, Smooth-On, Easton, PA) 2 RS-385 Motor with camshaft on syringe 100 max Not reported Fieseler et al. [10] Motion artifact generation in PET-MR Deformable left ventricle model (BSI, Germany), Lumirem® and 18F-FDG 1 Hydraulic flow system 50 Not reported Irwan et al. [52] MRI sequence development Commercial Anthropomorphic heart phantom (Limbs & Things, Bristol, UK) 1 Gas pump 60–80 Not reported Cygan et al. [45] Strain imaging Cast polyvinyl alcohol 1 Pulsatile flow pump SuperPump (Vivitro, Canada) 2–220 150 max Tavakoli et al. [23] Cardiac tracking Cast polyvinyl alcohol 2 CardioFlow 5000 MR Programmable Physiological Flow Pump Not reported Not reported Corrado et al. [46] MRI sequence development 3D-printed polyvinyl alcohol mold for silicone 1 Pulsatile flow pump PD-1100 (BDC Laboratories, Wheat Ridge, CO) 80 Not reported Okafor et al. [47] MRI sequence development Not reported 1 Piston pump 70 Not reported Evans et al. [48] MRI image interpretation Polyethylene sponge covered in silicone rubber 1 Fluid pump 5–150 300 max Debatin et al. [49] Comparing CT and MRI 1 cm thick foam covered on both sides with vulcanized rubber 2 Dual-phase pulsatile flow pump 60 5–50 motion.

Article Title: Feasibility and Technical Aspects of Proximal Nellix-in-Nellix Extension for Late Caudal Endograft Migration.
Article Snippet: Silicone anatomical models were used in conjunction with a pulsatile flow pump (SuperPump; Vivitro Labs Inc, Victoria, British Columbia, Canada).



Similar Products

90
ViVitro Labs Inc pulsatile flow pump superpump
Pulsatile Flow Pump Superpump, supplied by ViVitro Labs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/pulsatile+flow+pump+superpump/pulsatile+pump+superpump+ar+series/pm38739218-171-197-207
Average 90 stars, based on 1 article reviews
pulsatile flow pump superpump - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results